Environmental stability of SARS-CoV-2 on different types of surfaces under indoor and seasonal climate conditions
This article has been Reviewed by the following groups
Discuss this preprint
Start a discussion What are Sciety discussions?Listed in
- Evaluated articles (ScreenIT)
Abstract
We report the stability of SARS-CoV-2 on various surfaces under indoor, summer and spring/fall conditions. The virus was more stable under the spring/fall condition with virus half-lives ranging from 17.11 to 31.82 hours, whereas under indoor and summer conditions the virus half-lives were 3.5–11.33 and 2.54–5.58 hours, respectively.
Article activity feed
-
SciScore for 10.1101/2020.08.30.274241: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
Software and Algorithms Sentences Resources Clean Processed & Sterile, White), N95 mask (3M N95 mask 1870), cloth (65% polyester and 35% cotton from local source), styrofoam (50mL centrifuge tube-foam rack, CELLTREAT Scientific Products), cardboard (inner packing, TPP T75 flask), concrete (Fast-setting concrete mix, The Home Depot), rubber (The Home Depot), glass (Electron Microscopy Sciences), polypropylene (biohazard autoclave bag, ThermoFisher), stainless steel (Metal Remnant Inc.), and galvanized steel (The Home … SciScore for 10.1101/2020.08.30.274241: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
Software and Algorithms Sentences Resources Clean Processed & Sterile, White), N95 mask (3M N95 mask 1870), cloth (65% polyester and 35% cotton from local source), styrofoam (50mL centrifuge tube-foam rack, CELLTREAT Scientific Products), cardboard (inner packing, TPP T75 flask), concrete (Fast-setting concrete mix, The Home Depot), rubber (The Home Depot), glass (Electron Microscopy Sciences), polypropylene (biohazard autoclave bag, ThermoFisher), stainless steel (Metal Remnant Inc.), and galvanized steel (The Home Depot). ThermoFishersuggested: (ThermoFisher; SL 8; Centrifuge, RRID:SCR_020809)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
-