SalivaDirect: A simplified and flexible platform to enhance SARS-CoV-2 testing capacity
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
No abstract available
Article activity feed
-
SciScore for 10.1101/2020.08.03.20167791: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement IRB: Ethics: The collection of clinical samples from COVID-19 inpatients and healthcare workers at the Yale-New Haven Hospital was approved by the Institutional Review Board of the Yale Human Research Protection Program (Protocol ID. 2000027690).
Consent: Informed consent was obtained from all patients and healthcare workers prior to sample collection.Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
Software and Algorithms Sentences Resources The collection of deidentified specimens from healthy or asymptomatic individuals from the NBA was approved by the Institutional Review Board … SciScore for 10.1101/2020.08.03.20167791: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement IRB: Ethics: The collection of clinical samples from COVID-19 inpatients and healthcare workers at the Yale-New Haven Hospital was approved by the Institutional Review Board of the Yale Human Research Protection Program (Protocol ID. 2000027690).
Consent: Informed consent was obtained from all patients and healthcare workers prior to sample collection.Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
Software and Algorithms Sentences Resources The collection of deidentified specimens from healthy or asymptomatic individuals from the NBA was approved by the Institutional Review Board of the Yale Human Research Protection Program (Protocol ID. 2000028394). Yale Human Research Protection Programsuggested: NoneSaliva specimens were tested in triplicate and were treated with ThermoFisher Scientific proteinase K and tested with the ThermoFisher TaqPath RT-qPCR kit on the Bio-Rad CFX96. ThermoFisher TaqPathsuggested: NoneCombined AN/OP swabs were collected by Quest and followed their EUA specimen collection guidelines (Quest Diagnostics, 2020; U.S. Food & Drug Administration, 2020e). Questsuggested: (QUEST, RRID:SCR_005210)Statistical analysis: GraphPad Prism 8.3.0 was used to make the figures and perform all statistical analyses. GraphPad Prismsuggested: (GraphPad Prism, RRID:SCR_002798)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: We detected the following sentences addressing limitations in the study:Limitations of use: Our intended use of SalivaDirect is for the clear and liquid saliva that naturally pools in the mouth. The protocol as currently written is not intended for use of hospitalized COVID-19 patients who are unable to produce “true” saliva. While our previous analysis indicates that saliva is more sensitive for SARS-CoV-2 detection than nasopharyngeal swabs in COVID-19 inpatients (Wyllie et al., 2020), saliva from patients can contain blood or mucus, which can interfere with PCR or make it difficult to pipet. We can overcome many of these issues by having specific collection procedures for saliva collection and using proteinase K to make samples easier to pipet, but some samples can still be invalid if they are not collected properly. While we show that invalid samples are rare from our NBA cohort, our study was biased towards adult men. Saliva collection techniques for adolescents and children, in particular, still need to be refined. Despite the simplified protocol, SalivaDirect is not a rapid point-of-care test and still requires a complex laboratory. Our method requires electricity and specialized RT-qPCR instruments which can be a limiting factor when such equipment is not available, especially in low- and middle-income countries. Target populations and future improvements: To date, there is only one SARS-CoV-2 laboratory diagnostic test authorized by the FDA for asymptomatic testing (U.S. Food & Drug Administration, 2020d), and additional authorized tests...
Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
-
-