COVIDPEN: A Novel COVID-19 Detection Model using Chest X-Rays and CT Scans
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
The trending global pandemic of COVID-19 is the fastest ever impact which caused people worldwide by severe acute respiratory syndrome (SARS)-driven coronavirus. However, several countries suffer from the shortage of test kits and high false negative rate in PCR test. Enhancing the chest X-ray or CT detection rate becomes critical. The patient triage is of utmost importance and the use of machine learning can drive the diagnosis of chest X-ray or CT image by identifying COVID-19 cases. To tackle this problem, we propose COVIDPEN - a transfer learning approach on Pruned EfficientNet-based model for the detection of COVID-19 cases. The proposed model is further interpolated by post-hoc analysis for the explainability of the predictions. The effectiveness of our proposed model is demonstrated on two systematic datasets of chest radiographs and computed tomography scans. Experimental results with several baseline comparisons show that our method is on par and confers clinically explicable instances, which are meant for healthcare providers.
Article activity feed
-
SciScore for 10.1101/2020.07.08.20149161: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
No key resources detected.
Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar …
SciScore for 10.1101/2020.07.08.20149161: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
No key resources detected.
Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
-