COVID Faster R-CNN: A Novel Framework to Diagnose Novel Coronavirus Disease (COVID-19) in X-Ray Images
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
COVID-19 or novel coronavirus disease, which has already been declared as a worldwide pandemic, at first had an outbreak in a small town of China, named Wuhan. More than two hundred countries around the world have already been affected by this severe virus as it spreads by human interaction. Moreover, the symptoms of novel coronavirus are quite similar to the general flu. Screening of infected patients is considered as a critical step in the fight against COVID-19. Therefore, it is highly relevant to recognize positive cases as early as possible to avoid further spreading of this epidemic. However, there are several methods to detect COVID-19 positive patients, which are typically performed based on respiratory samples and among them one of the critical approach which is treated as radiology imaging or X-Ray imaging. Recent findings from X-Ray imaging techniques suggest that such images contain relevant information about the SARS-CoV-2 virus. In this article, we have introduced a Deep Neural Network (DNN) based Faster Regions with Convolutional Neural Networks (Faster R-CNN) framework to detect COVID-19 patients from chest X-Ray images using available open-source dataset. Our proposed approach provides a classification accuracy of 97.36%, 97.65% of sensitivity, and a precision of 99.28%. Therefore, we believe this proposed method might be of assistance for health professionals to validate their initial assessment towards COVID-19 patients.
Article activity feed
-
SciScore for 10.1101/2020.05.14.20101873: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
NIH rigor criteria are not applicable to paper type.Table 2: Resources
Software and Algorithms Sentences Resources For the model building and training, we have used the Googles TensorFlow library and VGG-16 for high-performance numerical computation. TensorFlowsuggested: (tensorflow, RRID:SCR_016345)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were …
SciScore for 10.1101/2020.05.14.20101873: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
NIH rigor criteria are not applicable to paper type.Table 2: Resources
Software and Algorithms Sentences Resources For the model building and training, we have used the Googles TensorFlow library and VGG-16 for high-performance numerical computation. TensorFlowsuggested: (tensorflow, RRID:SCR_016345)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
-
-