Rapid, large-scale, and effective detection of COVID-19 via non-adaptive testing
This article has been Reviewed by the following groups
Discuss this preprint
Start a discussion What are Sciety discussions?Listed in
- Evaluated articles (ScreenIT)
Abstract
Pooling of samples can increase lab capacity when using Polymerase chain reaction (PCR) to detect diseases such as COVID-19. However, pool testing is typically performed via an adaptive testing strategy which requires a feedback loop in the lab and at least two PCR runs to confirm positive results. This can cost precious time. We discuss a non-adaptive testing method where each sample is distributed in a prescribed manner over several pools, and which yields reliable results after one round of testing. More precisely, assuming knowledge about the overall incidence rate, we calculate explicit error bounds on the number of false positives which scale favourably with pool size and sample multiplicity. This allows for hugely streamlined PCR testing and cuts in detection times for a large-scale testing scenario. A viable consequence of this method could be real-time screening of entire communities, frontline healthcare workers and international flight passengers, for example, using the PCR machines currently in operation.
Article activity feed
-
SciScore for 10.1101/2020.04.06.028431: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
No key resources detected.
Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar …
SciScore for 10.1101/2020.04.06.028431: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Table 2: Resources
No key resources detected.
Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- No funding statement was detected.
- No protocol registration statement was detected.
-
