Simultaneous monitoring of HIV viral load and screening of SARS-CoV-2 employing a low-cost RT-qPCR test workflow
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
This new workflow enables co-extraction of HIV and SARS-CoV2 RNAs from clinical pooled plasma/nasal secretion samples that allows sensitive detection of SARS-CoV-2 and HIV infections in the patients-living with HIV.
Article activity feed
-
-
SciScore for 10.1101/2021.08.18.21256786: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics Consent: Informed consent was obtained from adult participants and parents or permanent legal guardians of participant children.
IRB: Participants from CIENI/INER gave written consent for the use of remnant plasma samples, approved by the Institutional Review Board of the National Institute of Respiratory Diseases (Project code: E02-17)Sex as a biological variable not detected. Randomization We randomly selected at least 30 specimens to allow estimation of VL. Blinding not detected. Power Analysis not detected. Table 2: Resources
Software and Algorithms Sentences Resources HIV VL was measured in all the selected samples using the Abbott m2000 system (Chicago, IL) and known to contain near or above 1000 … SciScore for 10.1101/2021.08.18.21256786: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics Consent: Informed consent was obtained from adult participants and parents or permanent legal guardians of participant children.
IRB: Participants from CIENI/INER gave written consent for the use of remnant plasma samples, approved by the Institutional Review Board of the National Institute of Respiratory Diseases (Project code: E02-17)Sex as a biological variable not detected. Randomization We randomly selected at least 30 specimens to allow estimation of VL. Blinding not detected. Power Analysis not detected. Table 2: Resources
Software and Algorithms Sentences Resources HIV VL was measured in all the selected samples using the Abbott m2000 system (Chicago, IL) and known to contain near or above 1000 copies/mL HIV RNA. Abbottsuggested: (Abbott, RRID:SCR_010477)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
Results from scite Reference Check: We found no unreliable references.
-