The emergence and rapid spread of the Omicron variant of SARS-CoV-2, which has more than 30 substitutions in the spike glycoprotein, compromises the efficacy of currently available vaccines and therapeutic antibodies. Using a clinical strain of the Omicron variant, we analyzed the neutralizing power of eight currently used monoclonal antibodies compared to the ancestral B.1 BavPat1 D614G strain. We observed that six of these antibodies have lost their ability to neutralize the Omicron variant. Of the antibodies still having neutralizing activity, Sotrovimab/Vir-7831 shows the smallest reduction in activity, with a factor change of 3.1. Cilgavimab/AZD1061 alone shows a reduction in efficacy of 15.8, resulting in a significant loss of activity for the Evusheld cocktail (42.6-fold reduction) in which the other antibody, Tixagevimab, does not retain significant activity against Omicron. Our results suggest that the clinical efficacy of the initially proposed doses should be rapidly evaluated and the possible need to modify doses or propose combination therapies should be considered.
Article activity feed
-
-
SciScore for 10.1101/2022.01.01.474639: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics not detected. Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Cell Line Authentication not detected. Table 2: Resources
Experimental Models: Cell Lines Sentences Resources Cell line: VeroE6/TMPRSS2 cells (ID 100978) were obtained from CFAR and were grown in minimal essential medium (Life Technologies) with 7⍰. VeroE6/TMPRSS2suggested: JCRB Cat# JCRB1819, RRID:CVCL_YQ49)Software and Algorithms Sentences Resources All data obtained were analyzed using GraphPad Prism 7 software (Graphpad software). GraphPad Prismsuggested: (GraphPad Prism, RRID:SCR_002798)Graphpadsuggested: (GraphPad, RRID:SCR_000306)Results from OddPub: We did not detect …
SciScore for 10.1101/2022.01.01.474639: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics not detected. Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Cell Line Authentication not detected. Table 2: Resources
Experimental Models: Cell Lines Sentences Resources Cell line: VeroE6/TMPRSS2 cells (ID 100978) were obtained from CFAR and were grown in minimal essential medium (Life Technologies) with 7⍰. VeroE6/TMPRSS2suggested: JCRB Cat# JCRB1819, RRID:CVCL_YQ49)Software and Algorithms Sentences Resources All data obtained were analyzed using GraphPad Prism 7 software (Graphpad software). GraphPad Prismsuggested: (GraphPad Prism, RRID:SCR_002798)Graphpadsuggested: (GraphPad, RRID:SCR_000306)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
Results from scite Reference Check: We found no unreliable references.
-