Rapid single-molecule detection of COVID-19 and MERS antigens via nanobody-functionalized organic electrochemical transistors
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
No abstract available
Article activity feed
-
-
SciScore for 10.1101/2020.11.12.20228874: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement IRB: Clinical Sample Preparation and Testing: The samples (saliva samples and nasopharyngeal swabs) used in this study (Fig. 5) were collected from human subjects as part of registered protocols approved by the Institutional Review Board of King Faisal Specialist Hospital & Research Center and KAUST Institutional Biosafety and Bioethics Committee (IBEC).
Consent: All volunteers provided signed consent to participate in the study.Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable Human serum from human male AB plasma was purchased from Sigma-Aldrich and used as-received. Table 2: Resources
Software and Algorithms Se… SciScore for 10.1101/2020.11.12.20228874: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement IRB: Clinical Sample Preparation and Testing: The samples (saliva samples and nasopharyngeal swabs) used in this study (Fig. 5) were collected from human subjects as part of registered protocols approved by the Institutional Review Board of King Faisal Specialist Hospital & Research Center and KAUST Institutional Biosafety and Bioethics Committee (IBEC).
Consent: All volunteers provided signed consent to participate in the study.Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable Human serum from human male AB plasma was purchased from Sigma-Aldrich and used as-received. Table 2: Resources
Software and Algorithms Sentences Resources Purification columns and SPR materials were purchased from GE Healthcare: HisTrap-HP 5 ml, StrepTrap-HP 5 ml, Superdex75 16/600, Biacore NTA SPR sensor chips (BR100034). GE Healthcaresuggested: (GE Healthcare, RRID:SCR_000004)Protein sequences were reverse-translated and codon-optimized for expression in E. coli with an in-house Python script based on DNAChisel54. Pythonsuggested: (IPython, RRID:SCR_001658)Results from OddPub: Thank you for sharing your data.
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
-