Quick and Easy Assembly of a One-Step qRT-PCR Kit for COVID-19 Diagnostics Using In-House Enzymes

This article has been Reviewed by the following groups

Read the full article See related articles

Abstract

No abstract available

Article activity feed

  1. SciScore for 10.1101/2020.07.31.20165704: (What is this?)

    Please note, not all rigor criteria are appropriate for all manuscripts.

    Table 1: Rigor

    Institutional Review Board Statementnot detected.
    Randomizationnot detected.
    Blindingnot detected.
    Power Analysisnot detected.
    Sex as a biological variablenot detected.
    Cell Line Authenticationnot detected.

    Table 2: Resources

    Experimental Models: Cell Lines
    SentencesResources
    The Sf9 cells were cultured in ESF 921 medium (Expression Systems) at 27°C with continuous shaking at 80 rpm for aeration.
    Sf9
    suggested: None
    Software and Algorithms
    SentencesResources
    The unit of His-Taq Pol’s activity was determined by interpolation from the standard curve using Prism8 software (GraphPad)
    GraphPad
    suggested: (GraphPad Prism, RRID:SCR_002798)
    Then 1 µL of enzymes was added to the respective reaction of either MMLV-RT, ProtoScript® II (New England Labs, Cat No M0368), NEB AMV (New England Labs, Cat No M0277), Superscript II (Invitrogen, Cat. No 18064022), or Superscript III (Invitrogen, Cat. No 18080093).
    New England Labs
    suggested: None
    The one-step RT-qPCR was performed in ABI 7500 and 7900 Fast Real-Time PCR system (Applied Biosystems, USA) for the side-by-side comparison with the Invitrogen SuperScript™ III Platinum™ One-step RT-qPCR and Thermofisher TaqPath™ 1-Step RT-qPCR, respectively.
    Thermofisher TaqPath™
    suggested: None

    Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).


    Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.

    Results from TrialIdentifier: No clinical trial numbers were referenced.


    Results from Barzooka: We did not find any issues relating to the usage of bar graphs.


    Results from JetFighter: We did not find any issues relating to colormaps.


    Results from rtransparent:
    • Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
    • Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
    • No protocol registration statement was detected.

    About SciScore

    SciScore is an automated tool that is designed to assist expert reviewers by finding and presenting formulaic information scattered throughout a paper in a standard, easy to digest format. SciScore checks for the presence and correctness of RRIDs (research resource identifiers), and for rigor criteria such as sex and investigator blinding. For details on the theoretical underpinning of rigor criteria and the tools shown here, including references cited, please follow this link.