A SARS-CoV-2 Reference Standard Quantified by Multiple Digital PCR Platforms for Quality Assessment of Molecular Tests
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
Article activity feed
-
SciScore for 10.1101/2020.09.14.20193904: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Cell Line Authentication not detected. Table 2: Resources
Experimental Models: Cell Lines Sentences Resources The strain was cultured with Vero cells (ATCC® CCL-81) at 37°C in a 5% carbon dioxide incubator. Verosuggested: NoneSoftware and Algorithms Sentences Resources Probit regression analysis of 95% hit rates was performed with SPSS 16.0 software (SPSS Inc, Chicago, IL). SPSSsuggested: (SPSS, RRID:SCR_002865)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when …
SciScore for 10.1101/2020.09.14.20193904: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Cell Line Authentication not detected. Table 2: Resources
Experimental Models: Cell Lines Sentences Resources The strain was cultured with Vero cells (ATCC® CCL-81) at 37°C in a 5% carbon dioxide incubator. Verosuggested: NoneSoftware and Algorithms Sentences Resources Probit regression analysis of 95% hit rates was performed with SPSS 16.0 software (SPSS Inc, Chicago, IL). SPSSsuggested: (SPSS, RRID:SCR_002865)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
-
-