Accuracy and real life performance of a novel interferon-γ release assay for the detection of SARS-CoV2 specific T cell response
This article has been Reviewed by the following groups
Discuss this preprint
Start a discussion What are Sciety discussions?Listed in
- Evaluated articles (ScreenIT)
Abstract
Article activity feed
-
-
SciScore for 10.1101/2021.07.17.21260316: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics Consent: The Department of Occupational Medicine collected the HCW samples after informed consent.
IRB: Ethics: The study was approved by the ethics committee of Albert-Ludwigs University Freiburg (#20-1271Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Table 2: Resources
Antibodies Sentences Resources Detection of SARS-CoV-2 antibodies: We used the following SARS-CoV-2 immunoglobuline G (IgG) assays to rule out past infection in the no COVID-19 and in the vaccine cohorts: Anti-SARS-CoV-2 ELISA IgG, detecting IgG antibodies against S1 (EUROIMMUN, Lübeck, Anti-SARS-CoV-2 ELISA IgG, detecting IgGsuggested: NoneS1suggested: NoneGerma… SciScore for 10.1101/2021.07.17.21260316: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics Consent: The Department of Occupational Medicine collected the HCW samples after informed consent.
IRB: Ethics: The study was approved by the ethics committee of Albert-Ludwigs University Freiburg (#20-1271Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Table 2: Resources
Antibodies Sentences Resources Detection of SARS-CoV-2 antibodies: We used the following SARS-CoV-2 immunoglobuline G (IgG) assays to rule out past infection in the no COVID-19 and in the vaccine cohorts: Anti-SARS-CoV-2 ELISA IgG, detecting IgG antibodies against S1 (EUROIMMUN, Lübeck, Anti-SARS-CoV-2 ELISA IgG, detecting IgGsuggested: NoneS1suggested: NoneGermany); recomWell SARS-CoV-2 IgG detecting IgG antibodies against the nucleoprotein (N) (Mikrogen, Munich, SARS-CoV-2 IgG detecting IgGsuggested: NoneGermany); ADVIA Centaur SARS-CoV-2 total antibody (COV2T) assay, detecting total antibodies against S1-RBD (Siemens, Munich, Germany); and the Elecsys Anti-SARS-CoV-2, detecting total antibodies against N (Roche, Mannheim, Germany) S1-RBDsuggested: NoneAnti-SARS-CoV-2 , detecting total antibodies against N ( Roche , Mannheim , Germany)suggested: NoneSoftware and Algorithms Sentences Resources Statistical analysis: Data were analysed using IBM SPSS Statistics version 24 software (www.ibm.com/spss/statistics), SPSSsuggested: (SPSS, RRID:SCR_002865)GraphPad Prism version 9 (www.graphpad.com), and MedCalc version 19 (www.medcalc.com). GraphPad Prismsuggested: (GraphPad Prism, RRID:SCR_002798)MedCalcsuggested: (MedCalc, RRID:SCR_015044)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: We detected the following sentences addressing limitations in the study:Limitation for the use of such a biological assay is the functionality of the T-cell response. Even low-dose steroid treatment may interfere with IGRA testing, as has been shown for Quantiferon TB in immunocompetent children (34). We have seen in one of our patients that even short-term steroid treatment may be of relevance. The patient yielded a negative mitogen control and a negative response to SARS-CoV-2 antigen (46 and 15 mIU/ml) three weeks after vector/mRNA heterologous vaccination, but SARS-CoV-2 S1-IgG was detectable. She was on high dose steroids when blood was drawn, but not during vaccination. After stopping steroid treatment, we repeated the assay and detected 985 mIU/ml after antigen stimulation with high positive mitogen control (1880 mIU/ml). Further, the interpretation of grey-zone results is always difficult, so we developed a double cut-off strategy including BLANK results in result interpretation. Diagnostic test accuracy analysis showed best accuracy with similar negative predictive values using our adopted cut-off strategy. In conclusion, the EUROIMMUN IGRA is an easy to perform assay for the detection of specific T-cell response against SARS-CoV-2 spike antigen. The assay is highly specific and sensitive. During a performance evaluation of the assay we were able to show that patients on immunosuppressive regimens may have isolated T-cell or antibody response or in several cases do not respond at all. For clinical practice, we recommend asking for steroi...
Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
Results from scite Reference Check: We found no unreliable references.
-