SARS-CoV-2 elicits robust adaptive immune responses regardless of disease severity
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
No abstract available
Article activity feed
-
-
SciScore for 10.1101/2020.10.08.331645: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement Consent: Inclusion criteria were as follows; 1) Age above 18 years; 2) PCR verified SARS-CoV-2 within the preceding 12 weeks; 3) Full recovery from acute COVID-19 illness; 4) Able to give informed consent. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Cell Line Authentication not detected. Table 2: Resources
Antibodies Sentences Resources After sample incubation, bound IgG was detected by incubation with MSD SULFO-TAG Anti-Human IgG Antibody and subsequently measured on a MESO QuickPlex SQ 120 Reader (Cat. No. AI0AA-0) after addition of GOLD Read Buffer B (Cat. No. R60AM-2). Anti-Human IgGsuggested: NoneSciScore for 10.1101/2020.10.08.331645: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Institutional Review Board Statement Consent: Inclusion criteria were as follows; 1) Age above 18 years; 2) PCR verified SARS-CoV-2 within the preceding 12 weeks; 3) Full recovery from acute COVID-19 illness; 4) Able to give informed consent. Randomization not detected. Blinding not detected. Power Analysis not detected. Sex as a biological variable not detected. Cell Line Authentication not detected. Table 2: Resources
Antibodies Sentences Resources After sample incubation, bound IgG was detected by incubation with MSD SULFO-TAG Anti-Human IgG Antibody and subsequently measured on a MESO QuickPlex SQ 120 Reader (Cat. No. AI0AA-0) after addition of GOLD Read Buffer B (Cat. No. R60AM-2). Anti-Human IgGsuggested: NoneELISA: IgA antibodies were measured using the Anti-SARS-CoV-2 IgA ELISA from Euroimmun (Euroimmun Medizinische Labordiagnostika AG, Lübeck, Germany, Cat. No. El 2606-9601 A), according to manufacturer’s instructions. Anti-SARS-CoV-2 IgAsuggested: NoneIgA type antibodies were detected by incubation with peroxidase labelled anti-human IgA followed by a chromogen solution, resulting in color development in positive wells. anti-human IgAsuggested: NoneExperimental Models: Cell Lines Sentences Resources HEK293T cells were cultured in DMEM, containing 10% FBS and 50 U/mL P/S. HEK293Tsuggested: NoneAfter 1 hour of incubation at 37°C BHK-G43 cells were washed three times in PBS and fresh media was added. BHK-G43suggested: NoneSoftware and Algorithms Sentences Resources Data and Statistical analyses: Flow cytometry data was analyzed using FlowJo (Version 10.7.1). FlowJosuggested: (FlowJo, RRID:SCR_008520)All data was processed and graphed in GraphPad Prism version 8.4.3. GraphPad Prismsuggested: (GraphPad Prism, RRID:SCR_002798)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- No funding statement was detected.
- No protocol registration statement was detected.
-