Reliable estimation of SARS-CoV-2 anti-spike protein IgG titers from single dilution optical density values in serologic surveys
This article has been Reviewed by the following groups
Listed in
- Evaluated articles (ScreenIT)
Abstract
Article activity feed
-
-
SciScore for 10.1101/2022.02.13.22270904: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics Consent: Individuals who sleep 3 or more nights per week within the defined study area, are aged 2 years or older, and who provide consent (parental consent for minors) were eligible to participate.
IRB: This project was approved by the Human Research Ethics Committee of the Instituto Gonçalo Moniz, Fundação Oswaldo Cruz (FIOCRUZ), the National Research Ethics Council (CONEP) and the Yale University Research Ethics Committee.Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Table 2: Resources
Antibodies Sentences Resources Threshold for antibody detection: For the Euroimmun anti-S IgG ELISA, the manufacturer recommends that … SciScore for 10.1101/2022.02.13.22270904: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
Ethics Consent: Individuals who sleep 3 or more nights per week within the defined study area, are aged 2 years or older, and who provide consent (parental consent for minors) were eligible to participate.
IRB: This project was approved by the Human Research Ethics Committee of the Instituto Gonçalo Moniz, Fundação Oswaldo Cruz (FIOCRUZ), the National Research Ethics Council (CONEP) and the Yale University Research Ethics Committee.Sex as a biological variable not detected. Randomization not detected. Blinding not detected. Power Analysis not detected. Table 2: Resources
Antibodies Sentences Resources Threshold for antibody detection: For the Euroimmun anti-S IgG ELISA, the manufacturer recommends that samples with normalized OD values <0.8 are considered negative, those with values >=0.8 and <1.1 considered borderline, and those with values >=1.1 considered positive. IgG ELISAsuggested: NoneSoftware and Algorithms Sentences Resources Interpolated titers were computed using the software GraphPad Prism (Version 5.01, GraphPad software, San Diego, USA). GraphPad Prismsuggested: (GraphPad Prism, RRID:SCR_002798)GraphPadsuggested: (GraphPad Prism, RRID:SCR_002798)Results from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: An explicit section about the limitations of the techniques employed in this study was not found. We encourage authors to address study limitations.Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
Results from scite Reference Check: We found no unreliable references.
-