The impact of the undetected COVID-19 cases on its transmission dynamics
This article has been Reviewed by the following groups
Discuss this preprint
Start a discussion What are Sciety discussions?Listed in
- Evaluated articles (ScreenIT)
Abstract
Article activity feed
-
-
SciScore for 10.1101/2020.05.30.20117838: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
NIH rigor criteria are not applicable to paper type.Table 2: Resources
Experimental Models: Organisms/Strains Sentences Resources The infection matrix F and the transition matrix V are given by – where, , and w1 = (γ + μ + w) The basic reproduction number R0 of the model (1), is defined by the spectral radius of the next-generation matrix FV−1, therefore,
Or
where, R1, R2, R3 and R4 gives the quantification of the disease risk through susceptible-to-exposed, susceptible-to-infected detected, susceptible-to-infected undetected, and environment-to-human transmission routes, respectively.
w1 = (γ + μ + wsuggested: NoneResults from OddPub: We did not detect open data. We also did not detect open code. …
SciScore for 10.1101/2020.05.30.20117838: (What is this?)
Please note, not all rigor criteria are appropriate for all manuscripts.
Table 1: Rigor
NIH rigor criteria are not applicable to paper type.Table 2: Resources
Experimental Models: Organisms/Strains Sentences Resources The infection matrix F and the transition matrix V are given by – where, , and w1 = (γ + μ + w) The basic reproduction number R0 of the model (1), is defined by the spectral radius of the next-generation matrix FV−1, therefore,
Or
where, R1, R2, R3 and R4 gives the quantification of the disease risk through susceptible-to-exposed, susceptible-to-infected detected, susceptible-to-infected undetected, and environment-to-human transmission routes, respectively.
w1 = (γ + μ + wsuggested: NoneResults from OddPub: We did not detect open data. We also did not detect open code. Researchers are encouraged to share open data when possible (see Nature blog).
Results from LimitationRecognizer: We detected the following sentences addressing limitations in the study:Despite these strengths, this study has a few weaknesses. Since, the basic reproduction number was estimated by taking some parameter values from other studies and an approximated value of the number of undetected cases, the findings of this model may differ slightly from its actual value.
Results from TrialIdentifier: No clinical trial numbers were referenced.
Results from Barzooka: We did not find any issues relating to the usage of bar graphs.
Results from JetFighter: We did not find any issues relating to colormaps.
Results from rtransparent:- Thank you for including a conflict of interest statement. Authors are encouraged to include this statement when submitting to a journal.
- Thank you for including a funding statement. Authors are encouraged to include this statement when submitting to a journal.
- No protocol registration statement was detected.
-
